Projekt

Allgemein

Profil

Aktionen

Wiki » Historie » Revision 62

« Zurück | Revision 62/63 (diff) | Weiter »
Maximilian Seesslen, 07.10.2025 15:24


Eval
Schematics

Wiki

(Polnisch fuer Ausfall, Stoerung)

Reboot tests for nodes in order to
  • Test RTC persistence (Does RTC battery still work)
  • Test bootup issues (delay for flash chips) (CANDIS SPI Flash issues)
  • Test battery livetime (How long does miniminutnik run on one charged battery)

Parts

  • PI5C3257QE; 4xSPDT; 1 Schalter; 0.229€; 2 of them.
  • N+P-MOSFET for power switching
  • Button for device switching
  • Orange-LED: Target is on; Violet LED: Target is off (Awira is connected); Orange-Blinking: Test running; Violett-Blinking: Test running; Alternating: Target powered only
  • Red-Blinking: Test failed; Red-On: Test succeeded
  • 3V output e.g. for Miniminutnik reboot tests
  • 5V Input when CAN (-connector) is not available
  • Transceiver, STM32F072, voltage regulator

Behaviour

Awaria has Debug+CANBus 'input' which can be disconnected by electrical switches
To the own debug output either target device or awarias UART is routed.
A running test is interrupted

Open points

  • Measure current? I don't have a 'nice' device which does such thing yet. Here an additional UART would make sense to access Awaria while target is running. But power and routing is seperated.

Von Maximilian Seesslen vor 1 Tag aktualisiert · 62 Revisionen